{"id":702,"date":"2018-05-03T06:23:20","date_gmt":"2018-05-03T06:23:20","guid":{"rendered":"http:\/\/www.fhopepack.com\/videos\/?p=702"},"modified":"2026-11-06T16:46:33","modified_gmt":"2026-11-06T16:46:33","slug":"top-quality-upender-and-tilter-for-coil-mold","status":"publish","type":"post","link":"https:\/\/www.fhopepack.com\/videos\/top-quality-upender-and-tilter-for-coil-mold\/","title":{"rendered":"Coil and Mold Upenders: 90\u00b0 Hydraulic Tilters for Stamping and Tooling"},"content":{"rendered":"<blockquote>\n<p><strong>Executive Summary<\/strong><\/p>\n<p>In metal stamping plants and toolrooms, turning heavy raw coils and press dies through 90\u00b0 is an everyday necessity fraught with mechanical risk. A coil is an unstable cylinder subject to rolling and localized tangential stress; a stamping die is a dense rectangular block with an asymmetrical center of gravity (CoG). Attempting to tilt either payload using overhead crane slings frequently triggers rigging slip, side-loading, and violent tipping past the 45\u00b0 apex. Dedicated 90\u00b0 hydraulic upenders solve this by maintaining positive two-plane contact across the entire pivot arc. Engineered with dual pilot-operated counterbalance valves, reinforced L-cradles, and failsafe hydraulic locking, these machines stabilize the payload through every degree of rotation. From compact 2 t slit-coil lines to 50 t primary mill handlers and specialized 10 t to 40 t mold maintenance tables, hydraulic upenders eliminate plant floor impacts and ensure repeatable line-side throughput.<\/p>\n<\/blockquote>\n<iframe loading=\"lazy\" width=\"940\" height=\"535\" src=\"https:\/\/www.youtube.com\/embed\/TkKShaeWCW0\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen><\/iframe>\n<hr \/>\n<h2>Why upend a coil or a mold<\/h2>\n<p>Stamping and fabrication bays hold two heavy inventories \u2014 master strip coils and multi-ton press dies \u2014 and each arrives in the orientation the last process wanted, not the next one:<\/p>\n<ul>\n<li><strong>Coils<\/strong>: they arrive eye-horizontal (bore parallel to the floor) so they tie down and cannot roll in transit; line-side storage, strapping and rack staging want them eye-vertical, and the uncoiler wants them horizontal again. Each change is a 90\u00b0 turn.<\/li>\n<li><strong>Dies and molds<\/strong>: serviced flat on a bolster, then tilted 90\u00b0 to stand in the press for platen clamping.<\/li>\n<\/ul>\n<p>Doing that quarter-turn with a crane sling is where loads get dropped:<\/p>\n<p>When a load turns on a concrete floor via a crane, the pivot edge slides, slings scuff against sharp shoulders, and crossing the 45\u00b0 equilibrium point causes an uncontrollable drop. A dedicated hydraulic upender eliminates these hazards by securing the payload within an engineered L-shaped cradle supported on fixed mechanical pivot pins throughout the cycle.<\/p>\n<h2>90\u00b0 hydraulic tilt: how it works<\/h2>\n<p>A hydraulic upender turns cylinder stroke into a controlled 90\u00b0 sweep around a fixed pivot.<\/p>\n<ol>\n<li><strong>Force<\/strong>: a pump feeds one or two cylinders mounted between base and cradle.<\/li>\n<li><strong>Containment<\/strong>: the cradle turns on a fixed pivot shaft, and the load stays supported by two surfaces \u2014 the bed and the backstop \u2014 through the whole sweep.<\/li>\n<li><strong>Overcentre control<\/strong>: past the 45\u00b0 balance point gravity stops resisting and starts pulling, so counterbalance valves meter the rod-end discharge and keep the descent from lunging.<\/li>\n<\/ol>\n<h2>FPCT coil series by tonnage<\/h2>\n<p>A coil concentrates its mass on a narrow contact line, so the cradle has to hold it without letting it roll. The <a href=\"https:\/\/www.fhopepack.com\/Coil-Upender\/Hydraulic-Coil-Upender.html\">Hydraulic Coil Upender<\/a> FPCT series is built in tonnage steps:<\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left\">Series Model<\/th>\n<th style=\"text-align: left\">Rated Capacity<\/th>\n<th style=\"text-align: left\">Typical Drive Power<\/th>\n<th style=\"text-align: left\">Standard Cradle Configuration<\/th>\n<th style=\"text-align: left\">Application Target<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left\"><strong>FPCT-02<\/strong><\/td>\n<td style=\"text-align: left\">2 t (2,000 kg)<\/td>\n<td style=\"text-align: left\">as ordered<\/td>\n<td style=\"text-align: left\">V-deck per project<\/td>\n<td style=\"text-align: left\">Narrow slit rolls, copper strip, light coils<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\"><strong>FPCT-05<\/strong><\/td>\n<td style=\"text-align: left\">5 t (5,000 kg)<\/td>\n<td style=\"text-align: left\">as ordered<\/td>\n<td style=\"text-align: left\">V-deck per project<\/td>\n<td style=\"text-align: left\">Intermediate strip, slitting line off-take<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\"><strong>FPCT-10<\/strong><\/td>\n<td style=\"text-align: left\">10 t (10,000 kg)<\/td>\n<td style=\"text-align: left\">as ordered<\/td>\n<td style=\"text-align: left\">V-deck per project<\/td>\n<td style=\"text-align: left\">Medium stamping strip, standard sheet feed<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\"><strong>FPCT-20<\/strong><\/td>\n<td style=\"text-align: left\">20 t (20,000 kg)<\/td>\n<td style=\"text-align: left\">as ordered<\/td>\n<td style=\"text-align: left\">V-saddle per project<\/td>\n<td style=\"text-align: left\">Heavy automotive coils, master rolls<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\"><strong>FPCT-30<\/strong><\/td>\n<td style=\"text-align: left\">30 t (30,000 kg)<\/td>\n<td style=\"text-align: left\">as ordered<\/td>\n<td style=\"text-align: left\">V-bed per project<\/td>\n<td style=\"text-align: left\">Heavy gauge hot-rolled coils<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\"><strong>FPCT-50<\/strong><\/td>\n<td style=\"text-align: left\">50 t (50,000 kg)<\/td>\n<td style=\"text-align: left\">as ordered<\/td>\n<td style=\"text-align: left\">Dual-cylinder cradle per project<\/td>\n<td style=\"text-align: left\">Primary steel mill master coils<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Engineering Boundary Selection Rules<\/h3>\n<ul>\n<li><strong>The 8 t coil<\/strong>: an 8 t coil goes on FPCT-10, not FPCT-05 \u2014 the rated capacity is the number to size against, and dynamic moments during tilt only push you further above it. Size by the heaviest coil you will ever load, not the average.<\/li>\n<li><strong>Surface sensitivity<\/strong>: for cold-rolled, galvanized or copper strip, ask for a lined cradle \u2014 a replaceable polyurethane or similar liner protects the strip face from edge marking. Liner thickness and hardness are specified with the machine, not taken from a table.<\/li>\n<\/ul>\n<h2>FPMT mold upender and table size<\/h2>\n<p>Molds need a flat deck, not a V-saddle. The <a href=\"https:\/\/www.fhopepack.com\/mold-upender\/90-Degree-Mold-Upender-10T.html\">90 Degree Mold Upender 10T<\/a> page gives:<\/p>\n<ul>\n<li><strong>Flagship Model<\/strong>: FPMT-10<\/li>\n<li><strong>Rated Load Capacity<\/strong>: 10 t (10,000 kg)<\/li>\n<li><strong>Table Dimensions (Length \u00d7 Width \u00d7 Height)<\/strong>: 3000 mm \u00d7 2000 mm \u00d7 500 mm<\/li>\n<li><strong>Dead Weight (Machine Mass)<\/strong>: 10 t (10,000 kg)<\/li>\n<li><strong>Table Interface<\/strong>: Planar machined steel deck equipped with parallel clamping slots, T-slots, and clearance pockets for tooling leader pins and cooling manifolds.<\/li>\n<\/ul>\n<h3>Engineering Boundary Selection Rules<\/h3>\n<ul>\n<li><strong>The 12 t mold<\/strong>: FPMT-10 is rated 10 t, so a 12 t die belongs on the next size up (20 t) in the index. Molds carry eccentric mass \u2014 slides, manifolds, core pulls \u2014 so the load&#8217;s centre of gravity, not just its weight, decides whether the deck and clamps can hold it.<\/li>\n<li><strong>Extended Capacities<\/strong>: For facilities managing larger tooling portfolios, the broader <a href=\"https:\/\/www.fhopepack.com\/Coil-upender.html\">Coil Upender Index<\/a> provides dedicated 90\u00b0 mold upenders rated at 5 t, 10 t, 20 t, 30 t, and 40 t, as well as 180\u00b0 mold splitters rated at 5 t and 20 t for full toolroom disassembly.<\/li>\n<\/ul>\n<h2>Load, floor and foundation<\/h2>\n<p>Heavy upenders concentrate significant mass over a relatively compact footprint. Facility and civil engineers must verify floor slab capacity and reinforcement before installation.<\/p>\n<h3>Static Floor Loading Calculation (FPMT-10 Example)<\/h3>\n<p>Total Mass on Foundation = Machine Dead Weight + Rated Payload\nTotal Mass = 10,000 kg (Machine) + 10,000 kg (Rated Load) = 20,000 kg (20 t)<\/p>\n<p>Table Projected Base Area = Table Length \u00d7 Table Width\nBase Area = 3.0 m \u00d7 2.0 m = 6.0 m\u00b2<\/p>\n<p>Static Surface Pressure (q_static):\nq_static = Total Mass \/ Base Area\nq_static = 20,000 kg \/ 6.0 m\u00b2 = 3,333 kg\/m\u00b2 (~32.7 kN\/m\u00b2 or ~0.033 MPa)<\/p>\n<h3>Civil Foundation Requirements<\/h3>\n<ol>\n<li><strong>Dynamic factor<\/strong>: deceleration transfers load through the pivot trunnions, so the foundation is designed for the static pressure times a dynamic factor agreed with your structural engineer:\n<code>q_dynamic = q_static &times; factor<\/code> \u2014 with 32.7 kN\/m\u00b2 and a factor of 1.4, that is 45.8 kN\/m\u00b2. Use the factor your engineer signs off, not a catalogue default.<\/li>\n<li><strong>Floor<\/strong>: the slab is specified by that engineer for the dynamic pressure above; the machine drawing gives the anchor positions and the base area to design against.<\/li>\n<li><strong>Anchoring<\/strong>: the chassis is fixed with chemical anchors sized to the lateral tipping moment during an emergency stop \u2014 anchor size comes with the foundation drawing for your machine.<\/li>\n<\/ol>\n<h2>Cycle time you can measure<\/h2>\n<p>Standard catalog speeds are broad nominal approximations. In high-efficiency stamping bays, cycle times must be calculated based on physical hydraulic throughput and crane hook logistics:<\/p>\n<h3>Motion Cycle Formula<\/h3>\n<p>The total time for one complete 90\u00b0 handling operation (<code>T_cycle<\/code>) is defined as:<\/p>\n<p><code>T_cycle = t_load + t_tilt_up + t_dwell + t_tilt_return + t_unload<\/code><\/p>\n<p>Where:<\/p>\n<ul>\n<li><code>t_load<\/code>: Rigging and placement time via forklift tines, crane C-hook, or AGV.<\/li>\n<li><code>t_tilt_up<\/code>: 90\u00b0 rotation time under load (governed by pump flow rate <code>Q<\/code> and cylinder displacement volume <code>V_stroke<\/code>).<\/li>\n<li><code>t_dwell<\/code>: Inspection, coil unbanding, or clamp verification.<\/li>\n<li><code>t_tilt_return<\/code>: Cradle return stroke to starting position.<\/li>\n<li><code>t_unload<\/code>: Extraction time for downstream processing.<\/li>\n<\/ul>\n<h3>Operational Throughput Rate<\/h3>\n<p>To determine realistic hourly throughput:<\/p>\n<p><code>Throughput (cycles\/h) = 3600 \/ T_cycle<\/code><\/p>\n<p><em>Note on tilt time<\/em>: the 90\u00b0 stroke depends on pump displacement, set pressure and payload mass, and the pages do not publish a fixed figure. Commissioning speeds are set on site with the flow-control valve so the load moves without sloshing or shifting on the table \u2014 measure the stroke on your machine and use that number in planning.<\/p>\n<h2>Safety and clamping<\/h2>\n<p>Guarding and interlocks on an upender are set by the site risk assessment: the swept 90\u00b0 arc, the clamp path and the maintenance access to the pivot are the three zones to cover, and the interlock logic is confirmed against the machine you order.<\/p>\n<ul>\n<li>\n<p><strong>Hydraulic Line Rupture Protection<\/strong>: Hard-piped pilot-operated check valves and internal hose-burst velocity fuses are flanged directly onto cylinder bodies. If a hydraulic delivery hose shears or bursts, the valves lock hydraulic fluid inside the cylinder barrels, halting the cradle instantly.<\/p>\n<\/li>\n<li>\n<p><strong>Physical Maintenance Lockout (LOTO)<\/strong>: When maintenance personnel inspect hydraulic systems or pivot bushings beneath an elevated cradle, heavy structural steel mechanical locking pins (shot-pins) must be manually inserted to physically lock the cradle at 90\u00b0, isolating all gravitational energy.<\/p>\n<\/li>\n<li>\n<p><strong>Payload Clamping<\/strong>: Coil upenders utilize deep 120\u00b0 V-profiles to nest round loads. Mold upenders incorporate manual clamping bars, magnetic platens, or mechanical locating stops to prevent heavy dies from shifting sideways.<\/p>\n<\/li>\n<\/ul>\n<h2>Tooling and changeover<\/h2>\n<p>Modern stamping and tooling cells handle shifting production schedules that demand rapid changeover between disparate tool geometries:<\/p>\n<ul>\n<li><strong>Clearance Pockets and Leader Pin Relief<\/strong>: Die shoes feature protruding leader pins, guide bushings, and air couplings. The FPMT-10 platform features precision-machined transverse cutouts and T-slots. Tooling settles evenly on hardened resting surfaces without resting mass onto sensitive ground pins.<\/li>\n<li><strong>Modular V-Saddles for Dual-Purpose Lines<\/strong>: Plants handling both strip coils and stamping dies can equip a flat-deck upender with a bolt-on, detachable V-block or a flush-retractable hydraulic V-saddle. When down, the deck is completely flat for press tools; when raised, it provides the 120\u00b0 support needed for coils.<\/li>\n<li><strong>Quick-Change Alignment Stops<\/strong>: Adjustable perimeter locating blocks slide within machined keyways, enabling toolmakers to center asymmetrical molds over the cradle centerline within minutes.<\/li>\n<\/ul>\n<h2>Selection checklist<\/h2>\n<p>Use this engineering checklist to configure an upender matching your bay logistics:<\/p>\n<ol>\n<li><strong>Payload Type<\/strong>: Round coil (steel\/copper\/aluminum) or rectangular press tooling\/die block.<\/li>\n<li><strong>Maximum and Minimum Gross Weight<\/strong>: Total mass including master coil, pallets, die shoes, and handling brackets (confirm 8 t vs 10 t, 12 t vs 20 t boundaries).<\/li>\n<li><strong>Dimensional Range<\/strong>:<\/li>\n<\/ol>\n<ul>\n<li>For coils: Maximum and minimum outside diameter (OD), inside bore diameter (ID), and strip face width.<\/li>\n<li>For molds: Length, width, shut height, and maximum overhang beyond the deck perimeter.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li><strong>Center of Gravity Envelope<\/strong>: Specify mold asymmetry or coil bore offset to ensure correct cylinder sizing and counterbalance valve calibration.<\/li>\n<li><strong>Deck Configuration<\/strong>: 120\u00b0 V-saddle, vulcanized polyurethane lining, machined T-slots, or flush-recessed hybrid blocks.<\/li>\n<li><strong>Material Handling Interface<\/strong>: Loading via crane C-hook, magnet hoist, forklift pockets, or integrated motorized roller\/slat conveyors.<\/li>\n<li><strong>Control Architecture<\/strong>: Standalone push-button pendant, remote IP54 console, or factory PLC handshake (Profibus\/Profinet) for automated cells.<\/li>\n<\/ol>\n<h2>Engineering FAQ<\/h2>\n<h3>Can a single upender handle both round coils and square molds efficiently?<\/h3>\n<p>Yes. Multi-purpose units feature a flat structural deck fitted with a detachable, bolt-on V-saddle or an automated hydraulically recessed V-block. When lowered, the V-block sits flush with the table surface to accept flat molds. When elevated, it supports cylindrical coil diameters up to their full rated load.<\/p>\n<h3>Why choose hydraulic cylinders over electromechanical mechanical drives for loads above 10 t?<\/h3>\n<p>Hydraulics give high force from a compact package and, more importantly, counterbalance valves that hold back-pressure past the over-centre point, so an off-centre die cannot drop. A gear-rack or chain tilter has backlash and tooth loading to deal with at that same moment.<\/p>\n<h3>What pressure do these upenders run at?<\/h3>\n<p>The working pressure is set with the machine, from the cylinder area and the rated load \u2014 it is not a catalogue constant. Keep it low enough that the pump does not cook the oil on long cycles, and confirm the setting at commissioning.<\/p>\n<h3>How are precision mold guide pins protected from damage during upending?<\/h3>\n<p>The deck carries clearance channels and resting blocks so the die sits on its base plate, with guide pillars, spring manifolds and couplings hanging free in pockets instead of taking load.<\/p>\n<h2>Next step<\/h2>\n<ol>\n<li><strong>Send the load<\/strong>: maximum payload, coil OD\/ID\/width or mold L \u00d7 W \u00d7 H, to <strong>info@fhopepack.com<\/strong>.<\/li>\n<li><strong>Get the kinematics checked<\/strong>: centre of gravity and foundation pressure are calculated against your load, with GA and foundation drawings.<\/li>\n<li><strong>Receive the specification<\/strong>: hydraulic schematic, rated capacity and quotation for the model that fits.<\/li>\n<\/ol>\n<p><strong>Last reviewed:<\/strong> 2026-11-05<\/p>","protected":false},"excerpt":{"rendered":"<p>Executive Summary In metal stamping plants and toolrooms, turning heavy raw coils and press dies through 90\u00b0 is an everyday necessity fraught with mechanical risk. A coil is an unstable cylinder subject to rolling and [&hellip;]<\/p>","protected":false},"author":1,"featured_media":2647,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_seopress_titles_title":"Top Quality Upender and Tilter for Coil and Mold | FHOPE","_seopress_titles_desc":"One upender for coils and molds: what changes between the two loads, the cradle and V-deck, mold models of 10 t and 20 t, hydraulic drive, checklist and safety.","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"none","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":0,"_seopress_analysis_target_kw":"","_seopress_news_disabled":"","_seopress_video_disabled":"","_seopress_video":[],"_seopress_pro_schemas_manual":[{"_seopress_pro_rich_snippets_type":"none"}],"_seopress_pro_rich_snippets_disable_all":"","_seopress_pro_rich_snippets_disable":[],"_seopress_pro_schemas":[],"site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"fifu_image_url":"","fifu_image_alt":"","footnotes":""},"categories":[194],"tags":[202,191,192],"class_list":["post-702","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-tilterupender","tag-steel-coil-upender","tag-tilter","tag-upender"],"_links":{"self":[{"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/posts\/702","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/comments?post=702"}],"version-history":[{"count":11,"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/posts\/702\/revisions"}],"predecessor-version":[{"id":18356,"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/posts\/702\/revisions\/18356"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/media\/2647"}],"wp:attachment":[{"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/media?parent=702"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/categories?post=702"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/tags?post=702"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}