{"id":1423,"date":"2018-09-05T07:24:12","date_gmt":"2018-09-05T07:24:12","guid":{"rendered":"https:\/\/www.fhopepack.com\/videos\/?p=1423"},"modified":"2026-10-26T12:19:24","modified_gmt":"2026-10-26T12:19:24","slug":"fhope-pallet-inverter-with-dual-clamper","status":"publish","type":"post","link":"https:\/\/www.fhopepack.com\/videos\/fhope-pallet-inverter-with-dual-clamper\/","title":{"rendered":"Automatic Plastic Pipe and Tube Packing Line (FCL Series)"},"content":{"rendered":"<p>The FCL series automatic pipe coiling and strapping line provides in-line coiling, length metering, cutting, and radial strapping for small-bore flexible thermoplastic pipes including PE, PEX, PE-RT, PA, and PU tubing (OD 4 mm to 63 mm). Engineered to interface directly with continuous extrusion haul-offs, the system stabilizes line tension, eliminates manual reel changes, and delivers compacted, tied coils ready for storage or direct carton packaging.<\/p>\n<iframe loading=\"lazy\" width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/IzybASHDZ08\" frameborder=\"0\" allowfullscreen><\/iframe>\n<hr \/>\n<h2>Working Principle<\/h2>\n<p>The FCL packaging line integrates four synchronized electromechanical modules on a heavy-duty welded steel chassis: a pneumatic dancer tension control unit, a servo-driven precision length metering counter, a vertical cantilevered expanding reel coiler, and an automatic through-core strapping mechanism.<\/p>\n<pre><code>Extruder \/ Haul-off \u2500\u2500&gt; Dancer Accumulator \u2500\u2500&gt; Metering Rollers \u2500\u2500&gt; Traverse Guide \u2500\u2500&gt; Expanding Reel Coiler \u2500\u2500&gt; Radial Strapping Unit \u2500\u2500&gt; Tilting Discharge Cradle<\/code><\/pre>\n<ol>\n<li><strong>Tension Regulated Intake<\/strong>: Flexible tubing exits the extrusion cooling bath and haul-off unit, entering the vertical dancer accumulator. The pneumatic float arm modulates back-tension (typically between 15 N and 85 N depending on tube wall thickness) to prevent tube ovalization or stretching.<\/li>\n<li><strong>Servo Traversing and Coiling<\/strong>: An optical encoder on dual ground-urethane metering wheels tracks linear footage with an accuracy of \u00b10.2%. The tubing enters the traverse distributor, which matches its lateral pitch (<code>Pitch = Tube OD + Clearance<\/code>) to the expanding reel&#8217;s rotational speed governed by the line PLC.<\/li>\n<li><strong>In-Line Cut and Clamp<\/strong>: Once the preset batch length is registered, the line clamping jaw grips the tube, an orbital pneumatic shear performs a clean, square cut without swarf, and the tail is retained against the outer coil wrap.<\/li>\n<li><strong>Through-Core Strapping<\/strong>: The radial strapping head feeds polypropylene (PP) or polyester (PET) strap through dedicated gaps between the expanded core segments, applying 2, 3, or 4 radial ties with heat-welded or friction joints.<\/li>\n<li><strong>Core Collapse and Coil Ejection<\/strong>: The reel segments collapse radially via a central pneumatic linkage. The front retaining arm swings open, allowing a hydraulic or pneumatic tilting cradle to lower the finished coil onto an exit gravity roller table.<\/li>\n<\/ol>\n<p>All core operating parameters\u2014pipe diameter, target length, strap count, core ID expansion, and line speed matching\u2014are governed via an industrial HMI touchscreen recipe system (Siemens S7-1200\/1500 controller via Profinet).<\/p>\n<hr \/>\n<h2>Key Features<\/h2>\n<ul>\n<li><strong>Vertical Space-Saving Architecture<\/strong>: Edge-oriented vertical coiling minimizes footprint while utilizing gravity to stabilize coil alignment during the strapping cycle.<\/li>\n<li><strong>Precision Dual-Wheel Metering<\/strong>: Non-slip urethane counter wheels with high-resolution incremental encoders guarantee consistent batch lengths, preventing product giveaways or short-length claims.<\/li>\n<li><strong>Pneumatically Expanding Coiling Core<\/strong>: Radial multi-segment mandrel expands and collapses pneumatically, maintaining cylindrical geometry during winding and rapid collapse for clean coil stripping.<\/li>\n<li><strong>Integrated High-Speed Strapping Mechanism<\/strong>: Applies tension-controlled radial straps through the coil eye; eliminates operator intervention in high-pinch hazard areas.<\/li>\n<li><strong>Extrusion Line Interlock Synchronization<\/strong>: Closed-loop 0\u201310 V or fieldbus communication dynamically tracks extruder haul-off acceleration and deceleration, preventing loop sagging or pipe necking.<\/li>\n<li><strong>Gentle Surface Handling<\/strong>: Guide rollers, traverse eyelets, and contact surfaces are lined with engineering plastics (UHMW-PE or POM) to prevent scratching on glossy, coated, or barrier-layer pipes.<\/li>\n<\/ul>\n<hr \/>\n<h2>Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left\">Model<\/th>\n<th style=\"text-align: left\">Tube OD Range<\/th>\n<th style=\"text-align: left\">Coil ID Range<\/th>\n<th style=\"text-align: left\">Max Coil OD<\/th>\n<th style=\"text-align: left\">Max Coil Width<\/th>\n<th style=\"text-align: left\">Max Line Speed<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left\"><strong>FCL100<\/strong><\/td>\n<td style=\"text-align: left\">4\u201312 mm<\/td>\n<td style=\"text-align: left\">150\u2013250 mm<\/td>\n<td style=\"text-align: left\">350 mm<\/td>\n<td style=\"text-align: left\">150 mm<\/td>\n<td style=\"text-align: left\">Up to 120 m\/min<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\"><strong>FCL200<\/strong><\/td>\n<td style=\"text-align: left\">8\u201328 mm<\/td>\n<td style=\"text-align: left\">200\u2013400 mm<\/td>\n<td style=\"text-align: left\">650 mm<\/td>\n<td style=\"text-align: left\">200 mm<\/td>\n<td style=\"text-align: left\">Up to 80 m\/min<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\"><strong>FCL600<\/strong><\/td>\n<td style=\"text-align: left\">8\u201328 mm<\/td>\n<td style=\"text-align: left\">380\u2013600 mm<\/td>\n<td style=\"text-align: left\">1,050 mm<\/td>\n<td style=\"text-align: left\">300 mm<\/td>\n<td style=\"text-align: left\">Up to 50 m\/min<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\"><strong>FCL800<\/strong><\/td>\n<td style=\"text-align: left\">12\u201332 mm<\/td>\n<td style=\"text-align: left\">490\u2013860 mm<\/td>\n<td style=\"text-align: left\">1,200 mm<\/td>\n<td style=\"text-align: left\">350 mm<\/td>\n<td style=\"text-align: left\">Up to 40 m\/min<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\"><strong>FCL1000<\/strong><\/td>\n<td style=\"text-align: left\">20\u201363 mm<\/td>\n<td style=\"text-align: left\">600\u20131,300 mm<\/td>\n<td style=\"text-align: left\">1,600 mm<\/td>\n<td style=\"text-align: left\">400 mm<\/td>\n<td style=\"text-align: left\">Up to 25 m\/min<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em>Note: Dimensions and maximum line speeds represent baseline configurations. Custom mandrel expansion strokes and heavy-wall traverse mechanisms can be engineered for rigid or larger-bore materials.<\/em><\/p>\n<hr \/>\n<h2>Engineering Calculation<\/h2>\n<h3>1. Coil Geometry and Layer Turn Modeling<\/h3>\n<p>Accurate coil diameter estimation requires calculating the center-line neutral axis diameter of each concentric layer to avoid cumulative length errors.<\/p>\n<p>Given:<\/p>\n<ul>\n<li>Pipe outer diameter: <code>d<\/code> (mm)<\/li>\n<li>Mandrel expanded core inner diameter: <code>ID<\/code> (mm)<\/li>\n<li>Traverse usable spool width: <code>W_coil<\/code> (mm)<\/li>\n<li>Required target length: <code>L_total<\/code> (m)<\/li>\n<\/ul>\n<p><strong>Turns per single layer (<code>n<\/code>):<\/strong><\/p>\n<p><code>n = floor(W_coil \/ d)<\/code><\/p>\n<p><strong>Center-line winding diameter of layer <code>k<\/code> (<code>D_center,k<\/code>):<\/strong><\/p>\n<p><code>D_center,k = ID + (2k - 1) &times; d<\/code><\/p>\n<p><strong>Linear length wound on layer <code>k<\/code> (<code>L_k<\/code>):<\/strong><\/p>\n<p><code>L_k = n &times; &pi; &times; (D_center,k \/ 1,000)<\/code>  [meters]<\/p>\n<p><strong>Cumulative length after <code>k<\/code> layers (<code>S_k<\/code>):<\/strong><\/p>\n<p><code>S_k = &Sigma; (from i = 1 to k) L_i<\/code><\/p>\n<p>Calculate sequentially until <code>S_k &ge; L_total<\/code>. The final coil outer diameter (<code>Coil OD<\/code>) is governed by the total completed layer count <code>k_max<\/code>:<\/p>\n<p><code>Coil OD = ID + 2 &times; k_max &times; d<\/code><\/p>\n<hr \/>\n<h3>2. Practical Calculation Example<\/h3>\n<p><em>Scenario<\/em>: Coiling a 200 m pack of 20 mm OD PEX barrier pipe on an <strong>FCL600<\/strong> station.<\/p>\n<ul>\n<li>Tube OD <code>d<\/code> = 20 mm<\/li>\n<li>Set core <code>ID<\/code> = 600 mm<\/li>\n<li>Usable coil width <code>W_coil<\/code> = 300 mm<\/li>\n<\/ul>\n<p><strong>Step 1: Turns per layer<\/strong>\n<code>n = floor(300 \/ 20) = 15 turns\/layer<\/code><\/p>\n<p><strong>Step 2: Layer-by-layer progressive accumulation<\/strong><\/p>\n<ul>\n<li><strong>Layer 1<\/strong> (<code>k = 1<\/code>):\n<code>D_center,1 = 600 + (2 &times; 1 - 1) &times; 20 = 620 mm<\/code>\n<code>L_1 = 15 &times; &pi; &times; 0.620 m = 29.22 m<\/code>\n<code>Cumulative = 29.22 m<\/code><\/li>\n<li><strong>Layer 2<\/strong> (<code>k = 2<\/code>):\n<code>D_center,2 = 600 + (2 &times; 2 - 1) &times; 20 = 660 mm<\/code>\n<code>L_2 = 15 &times; &pi; &times; 0.660 m = 31.10 m<\/code>\n<code>Cumulative = 60.32 m<\/code><\/li>\n<li><strong>Layer 3<\/strong> (<code>k = 3<\/code>):\n<code>D_center,3 = 700 mm<\/code> \u2192 <code>L_3 = 32.99 m<\/code> \u2192 <code>Cumulative = 93.31 m<\/code><\/li>\n<li><strong>Layer 4<\/strong> (<code>k = 4<\/code>):\n<code>D_center,4 = 740 mm<\/code> \u2192 <code>L_4 = 34.87 m<\/code> \u2192 <code>Cumulative = 128.18 m<\/code><\/li>\n<li><strong>Layer 5<\/strong> (<code>k = 5<\/code>):\n<code>D_center,5 = 780 mm<\/code> \u2192 <code>L_5 = 36.76 m<\/code> \u2192 <code>Cumulative = 164.94 m<\/code><\/li>\n<li><strong>Layer 6<\/strong> (<code>k = 6<\/code>):\n<code>D_center,6 = 820 mm<\/code> \u2192 <code>L_6 = 38.64 m<\/code> \u2192 <code>Cumulative = 203.58 m<\/code><\/li>\n<\/ul>\n<p>Target length 200 m is achieved midway through Layer 6 (<code>k_max = 6<\/code>).\n<strong>Final Coil OD:<\/strong>\n<code>Coil OD = 600 + (2 &times; 6 &times; 20) = 840 mm<\/code>\nThe resulting 840 mm OD is well within the 1,050 mm maximum envelope of the FCL600 frame.<\/p>\n<hr \/>\n<h3>3. Throughput and Cycle Time Balance<\/h3>\n<p>The winding phase duration (<code>t_wind<\/code>) is determined by extruder output velocity (<code>v_line<\/code>):<\/p>\n<p><code>t_wind = L_total \/ v_line<\/code><\/p>\n<p><em>Example<\/em>: At <code>v_line = 25 m\/min<\/code> for a 200 m coil, <code>t_wind = 200 \/ 25 = 8.0 minutes<\/code> (480 seconds).<\/p>\n<p>The automatic cycle (shear cut, 3 radial strap feeds\/welds, core retraction, and cradle down-tilting) consumes 35 to 50 seconds.<\/p>\n<ul>\n<li>In <strong>continuous single-coiler lines<\/strong>, a vertical multi-pass dancer accumulator with a storage capacity <code>L_acc &ge; v_line &times; t_cycle<\/code> absorbs extruder throughput during tying.<\/li>\n<li>In <strong>dual-spindle configurations<\/strong>, the tube automatically transfers to an alternate pre-expanded reel within 4 seconds, completely eliminating line throttling.<\/li>\n<\/ul>\n<hr \/>\n<h2>Selection Checklist<\/h2>\n<p>Prior to equipment specification, confirm the following production baseline data:<\/p>\n<ul>\n<li><strong>Pipe Substrate<\/strong>: Resin grade (HDPE, PEX-a\/b\/c, PE-RT, PA11\/12, Polyurethane) and flexural modulus.<\/li>\n<li><strong>Cross-Sectional Range<\/strong>: Minimum and maximum tube outside diameter (OD) and nominal wall thickness.<\/li>\n<li><strong>Coil Packaging Profile<\/strong>: Target core inner diameter (ID), maximum external package diameter (OD), and face width.<\/li>\n<li><strong>Extruder Line Speed<\/strong>: Nominal and peak haul-off velocity (m\/min).<\/li>\n<li><strong>Strapping Specifications<\/strong>: Band material (PP or PET), strap width (9 mm, 12 mm, or 16 mm), and number of radial ties (2, 3, 4, or 6).<\/li>\n<li><strong>Downstream Automation<\/strong>: Integration requirements for secondary stretch-film wrapping, automated bag insertion, or robotic palletizing.<\/li>\n<li><strong>Power &amp; Pneumatics<\/strong>: Line voltage (e.g., 380V\/480V 3-Phase 50\/60 Hz) and clean, dry plant air supply (\u2265 0.6 MPa).<\/li>\n<\/ul>\n<hr \/>\n<h2>Safety<\/h2>\n<p>The FCL series conforms to harmonized European machinery safety legislation and global operational guidelines:<\/p>\n<ul>\n<li><strong>EN 415-10<\/strong>: Packaging machines safety; mandates performance-level interlocks on moving traverse arms, rotary strapping guides, and coil ejection zones.<\/li>\n<li><strong>ISO 12100:2010<\/strong>: Safety of machinery \u2014 General principles for design, risk assessment, and hazard mitigation.<\/li>\n<li><strong>EN ISO 13849-1 (Cat 3 \/ PL d)<\/strong>: Dual-channel safety circuits governing emergency stop interlocks and electro-sensitive protective equipment (light curtains).<\/li>\n<\/ul>\n<p>Standard plant safety features include full-perimeter welded wire mesh guarding, coded magnetic interlock access gates, pneumatic dump valves for zero residual pressure during intervention, and accessible emergency-stop pushbuttons along the operational envelope.<\/p>\n<hr \/>\n<h2>FAQ<\/h2>\n<p><strong>How does the FCL handle flexible tubing versus stiff, thick-walled pipe?<\/strong>\nThe coiler incorporates variable-torque electronic regulation. For high-flexibility PU\/PE tubing, minimal back-tension is maintained to prevent necking. For stiff PEX or PE conduit, hydraulic or heavy-duty pneumatic assist rollers press the outer wrap against the mandrel to secure tight, uniform layer seating.<\/p>\n<p><strong>Can the system coil and tie corrugated conduit?<\/strong>\nYes. Corrugated profiles are processed using custom contoured guide wheels and soft-compound polyurethane traverse rollers to prevent crushing or deforming the pipe crown profile.<\/p>\n<p><strong>Is manual intervention required during continuous extrusion?<\/strong>\nIn fully automated cells equipped with a dancer accumulator and automated tilting cradle, the machine executes cutting, strapping, and coil ejection autonomously. The operator is only required to clear finished coils from the exit accumulation buffer.<\/p>\n<p><strong>Can the machine strap using different band materials?<\/strong>\nThe standard thermal sealing strapping head handles commercial embossed PP strapping. For heavy coils requiring high residual retention, a friction-weld head configured for PET strapping can be specified.<\/p>\n<hr \/>\n<h2>Next Steps<\/h2>\n<p>To verify machine sizing, cycle balancing, and floor layout for your extrusion line, provide your technical parameters (tube OD range, line speed, coil dimensions, and package weights) to our engineering department.<\/p>\n<ul>\n<li>Request an engineered integration drawing: Contact our application engineering team.<\/li>\n<li>Explore complementary packaging units: Review integrated horizontal orbital wrappers and in-line shrink-bundling modules.<\/li>\n<\/ul>\n<hr \/>\n<h2>Related Reading<\/h2>\n<ul>\n<li><a href=\"\/videos\/double-wall-hose-coiling-and-strapping-machine\/\">Double-Wall Hose Coiling &amp; Strapping Machine<\/a><\/li>\n<li><a href=\"\/videos\/automatic-plastic-pipe-coiler-and-strapping-machine-2\/\">Automatic Plastic Pipe Coiler &amp; Strapping Machine<\/a><\/li>\n<li><a href=\"\/videos\/automatic-tube-coiler-and-pipe-coiling-strapping-machine-3\/\">Tube Coiler &amp; Pipe Coiling Strapping Machine<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>The FCL series automatic pipe coiling and strapping line provides in-line coiling, length metering, cutting, and radial strapping for small-bore flexible thermoplastic pipes including PE, PEX, PE-RT, PA, and PU tubing (OD 4 mm to [&hellip;]<\/p>","protected":false},"author":1,"featured_media":2635,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_seopress_titles_title":"FHOPE Pallet Inverter with Dual Clamper FPFZ-C02","_seopress_titles_desc":"Our dual clamp pallet inverter grips a load top and bottom and turns it 180 degrees in about 25 s, for loads up to 2.0 t. Specs and a clamp-range example.","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"none","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":301,"_seopress_analysis_target_kw":"","_seopress_news_disabled":"","_seopress_video_disabled":"","_seopress_video":[],"_seopress_pro_schemas_manual":[],"_seopress_pro_rich_snippets_disable_all":"","_seopress_pro_rich_snippets_disable":[],"_seopress_pro_schemas":[],"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"fifu_image_url":"","fifu_image_alt":"","footnotes":""},"categories":[290],"tags":[259,293],"class_list":["post-1423","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-pallet-inverter","tag-pallet-inverter","tag-pallet-inverter-with-dual-clamper"],"_links":{"self":[{"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/posts\/1423","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/comments?post=1423"}],"version-history":[{"count":13,"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/posts\/1423\/revisions"}],"predecessor-version":[{"id":17624,"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/posts\/1423\/revisions\/17624"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/media\/2635"}],"wp:attachment":[{"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/media?parent=1423"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/categories?post=1423"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fhopepack.com\/videos\/wp-json\/wp\/v2\/tags?post=1423"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}